Basic Info.
Model NO.
YLC-3000
Alert System for Lamp
One Set
System Working Pressure Resistance
(0.6 MPa)6kg/Cm2
Raw Water Supplying
Running Water
Brand of Ballast
Beasun
Transport Package
Plywood Case Into Container
Specification
CE, SGS, ISO
Trademark
YLD
Origin
Jiangyin, Jiangsu
HS Code
8421219990
Production Capacity
5000 Sets/Year
Product Description
Biochemical pharmaceutical UV light sterilizer water treatment
Advantages:
- UV does not alter taste, odour, colour or pH of the water
- UV does not require the addition of chemicals
- UV does not impart toxic by-products into the water
- UV systems are compact and easy to install
- UV systems require very little maintenance
- Running costs are often lower than those of a household lightbulb.
UV Disinfection Systems Application
1. Food processing and industrial water disinfection
2. Hospitals, various laboratory water disinfection, and high levels of pathogenic water disinfection
3. Municipal water
4. Biochemical pharmaceutical, cosmetics production water disinfection
5. Aquatic products processing water disinfection
6. Swimming pool water disinfection
7. Seawater, freshwater aquaculture breeding water disinfection
8. Ultra-pure water for electronic industry, and so on
Principle of Operation
Ultraviolet disinfection systems typically utilize thin cylindrical bulbs capable of generating narrow band wavelength UV light in the 254 nm range, placed in close proximity to high-purity glass tubes through which the water flows. The unit must be sized to provide adequate dosage at the specified flowrate. The water to be treated must be sufficiently free of turbidity (sediment), iron, manganese and any colorant that could affect transmission of the 254 nm UV light. Manufacturers' specifications should be consulted.
Limitation of Use
The UV water disinfection system NOT intended for the treatment of water that has an obvious contamination or intentional source, such as raw sewage, nor is the unit intended to convert wastewater to microbiologically safe drinking water.
Water Quality (in)
Water quality plays a major role in the transmission of germicidal UV rays. It is recommended that the water does not exceed following maximum concentration levels
Maximum Concentration Levels (Very Important)
Iron≤ 0.3ppm(0.3mg/L)
Hardness≤ 7gpg(120mg/L)
Turbidity≤ 1NTU
Manganese≤ 0.05ppm(0.05mg/L)
Tannins≤ 0.1ppm(0.3mg/L)
UV Transmittance≥ 750‰
Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the UV transmission is not satisfactory, contact the factory.
UV wavelength (nm)
DOSAGE is the product of intensity & time
Dosage=intensity*time=micro watt/cm2*time=microwatt-seconds per square centimeter
(μ W-s/cm2)
Note: 1000μ W-s/cm2=1mj/cm2(milli-joule/cm2)
As a general guideline, the following are some typical UV transmission rates (UVT)
City water supplies850-980‰
De-ionized or Reverse Osmosis water950-980‰
Surface waters(lakes, rivers, etc)700-900‰
Ground water(wells)900-950‰
Other liquids10-990‰
Technical parameters:
Advantages:
- UV does not alter taste, odour, colour or pH of the water
- UV does not require the addition of chemicals
- UV does not impart toxic by-products into the water
- UV systems are compact and easy to install
- UV systems require very little maintenance
- Running costs are often lower than those of a household lightbulb.
UV Disinfection Systems Application
1. Food processing and industrial water disinfection
2. Hospitals, various laboratory water disinfection, and high levels of pathogenic water disinfection
3. Municipal water
4. Biochemical pharmaceutical, cosmetics production water disinfection
5. Aquatic products processing water disinfection
6. Swimming pool water disinfection
7. Seawater, freshwater aquaculture breeding water disinfection
8. Ultra-pure water for electronic industry, and so on
Principle of Operation
Ultraviolet disinfection systems typically utilize thin cylindrical bulbs capable of generating narrow band wavelength UV light in the 254 nm range, placed in close proximity to high-purity glass tubes through which the water flows. The unit must be sized to provide adequate dosage at the specified flowrate. The water to be treated must be sufficiently free of turbidity (sediment), iron, manganese and any colorant that could affect transmission of the 254 nm UV light. Manufacturers' specifications should be consulted.
Limitation of Use
The UV water disinfection system NOT intended for the treatment of water that has an obvious contamination or intentional source, such as raw sewage, nor is the unit intended to convert wastewater to microbiologically safe drinking water.
Water Quality (in)
Water quality plays a major role in the transmission of germicidal UV rays. It is recommended that the water does not exceed following maximum concentration levels
Maximum Concentration Levels (Very Important)
Iron≤ 0.3ppm(0.3mg/L)
Hardness≤ 7gpg(120mg/L)
Turbidity≤ 1NTU
Manganese≤ 0.05ppm(0.05mg/L)
Tannins≤ 0.1ppm(0.3mg/L)
UV Transmittance≥ 750‰
Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the UV transmission is not satisfactory, contact the factory.
UV wavelength (nm)
DOSAGE is the product of intensity & time
Dosage=intensity*time=micro watt/cm2*time=microwatt-seconds per square centimeter
(μ W-s/cm2)
Note: 1000μ W-s/cm2=1mj/cm2(milli-joule/cm2)
As a general guideline, the following are some typical UV transmission rates (UVT)
City water supplies850-980‰
De-ionized or Reverse Osmosis water950-980‰
Surface waters(lakes, rivers, etc)700-900‰
Ground water(wells)900-950‰
Other liquids10-990‰
Technical parameters:
model | Processing capacity (Ton/Hour) | power (W) | inlet and outlet (inch) | working pressure (Kg/cm 2 ) | malfunction alert for UV lamp | reactor dimension (cm) L×W×H | dimension of panel(cm) | anchor bolt (cm) | overall weight (Kg) |
YLCn-005 | 0.3 | 16 | 1/2" | 6 | matched | 30×6×11 | 5 | ||
YLCn-008 | 1 | 25 | 1/2" | 6 | matched | 47×6.3×11 | 10 | ||
YLCn-050 | 2 | 40 | 1" | 6 | matched | 100×9×20 | Φ8.9×25 (diameter×length) | 69×4×Φ1 | 25 |
YLCn-150 | 6 | 80 | 1+1/4" | 6 | matched | 100×11×23 | 69×4×Φ1 | 30 | |
YLCn-200 | 8 | 120 | 1+1/2" | 6 | matched | 100×15.9×30 | Φ8.9×45 (diameter×length) | 69×7×Φ1 | 35 |
YLCn-300 | 12 | 160 | 2" | 6 | matched | 100×15.9×32 | 69×7×Φ1 | 40 | |
YLC-050 | 2 | 40 | DN25/1" | 6 | matched | 100×8.9×30 | 25×30×12 (L×H×w) | 60×4×Φ1 | 45 |
YLC-150 | 6 | 80 | DN32/1 1/4 " | 6 | matched | 100×10.8×30 | 60×4×Φ1 | 50 | |
YLC-200 | 8 | 120 | DN40/1 1/2 " | 6 | matched | 100×15.9×40 | 60×7×Φ1 | 60 | |
YLC-300 | 12 | 160 | DN50/2" | 6 | matched | 100×15.9×40 | 60×7×Φ1 | 70 | |
YLC-360 | 15 | 200 | DN65/2 1/2" | 6 | matched | 100×15.9×40 | 50×78×25 (L×H×W) | 60×7×Φ1 | 120 |
YLC-500 | 20 | 240 | DN65/2 1/2" | 6 | matched | 100×21.9×50 | 60×11×Φ1.2 | 130 | |
YLC-600 | 25 | 280 | DN80/3" | 6 | matched | 100×21.9×50 | 60×11×Φ1.2 | 140 | |
YLC-700 | 30 | 320 | DN100/4" | 6 | matched | 100×21.9×50 | 60×11×Φ1.2 | 150 | |
YLC-1000 | 40 | 360 | DN100/4" | 6 | matched | 100×21.9×50 | 60×11×Φ1.2 | 160 | |
YLC-1200 | 50 | 400 | DN125/5" | 6 | matched | 100×21.9×50 | 60×11×Φ1.2 | 180 | |
YLC-1500 | 60 | 420 | DN150/6" | 6 | matched | 170×27.3×57 | 120×16×Φ1.4 | 210 | |
YLC-2000 | 80 | 560 | DN150/6" | 6 | matched | 170×27.3×57 | 120×16×Φ1.4 | 220 | |
YLC-2500 | 100 | 700 | DN150/6" | 6 | matched | 170×27.3×57 | 60×128×30 (W×H×T) | 120×16×Φ1.4 | 275 |
YLC-3000 | 125 | 840 | DN150/6" | 6 | matched | 173×27.3×57 | 120×16×Φ1.4 | 300 | |
YLC-4000 | 150 | 1120 | DN200/8" | 6 | matched | 173×32.5×65 | 120×20×Φ1.6 | 325 | |
YLC-5000 | 200 | 1400 | DN200/8" | 6 | matched | 173×37.7×72 | 120×22×Φ1.6 | 350 | |
YLC-7000 | 300 | 2100 | DN250/10" | 6 | matched | 175×42.6×80 | 120×24×Φ2.0 | 400 | |
YLC-10K | 400 | 2520 | DN250/10" | 6 | matched | 176×52.9×95 | 60×150×40 (W×H×T) | 120×28×Φ2.2 | 475 |
YLC-15K | 600 | 3080 | DN300/12" | 6 | matched | 176×78×110 | 120×32×Φ2.4 | 600 | |
YLC-20K | 800 | 3920 | DN350/14" | 6 | matched | confirmed | confirmed | confirmed | confirmed |
YLC-25K | 1000 | 4760 | DN350/14" | 6 | matched | confirmed | confirmed | confirmed |